It is outside what we read: a shipment type we don't sync, a shipment created before the agreed start date, or one with no legs yet. Shipments in Pending, Waiting or Hold come in as not yet active. Ask us to widen the scope if you need those shipments on the board.
Quantum Edge Integration Guide
Updated last week
TrackFlo connects to Quantum Edge by reading a read-only replica of your Quantum Edge database over a site-to-site VPN. Quantum Edge has no webhooks, so our integration service polls the replica: shipments every 2 minutes, new traces every minute. The integration is read-only today. TrackFlo does not write anything back to Quantum Edge.
What TrackFlo reads
Each pass re-reads every shipment still in progress and updates only what changed, so there is no change log or "last modified" column for you to set up.
Shipments, legs and stops, every 2 minutes: status, customer, equipment, commodity, weight, temperature range, reference numbers, carrier, driver, truck and trailer, and each stop's address, facility instructions, appointment window, arrival and departure.
Traces, every minute: each new trace becomes an update on the load's timeline, with its type, comment, author, location, and an ETA when the trace carries one. On the first connection we also load the last 24 hours of traces.
Location pings. A trace with coordinates updates the load's location. Pings that MacroPoint writes into Quantum Edge as traces are labelled MacroPoint in TrackFlo.
The reps on each shipment: the customer account manager and salesperson, the carrier rep who booked the load, and the carrier account manager, with their names and emails.
Carriers, twice an hour: name, MC, DOT and SCAC, plus each carrier's dispatch and after-hours contacts.
Your trace types, from your own trace-type table, so each update keeps the name your team uses in Quantum Edge.
By default we read truckload and partial shipments that are not yet delivered or cancelled and were created on or after a start date we agree with you. Other shipment types are left out unless you ask for them. A load TrackFlo already holds stays in the read until Quantum Edge shows it delivered or cancelled, which is how it leaves the board.
Quantum Edge statuses map to TrackFlo like this:
Quantum Edge status | In TrackFlo |
|---|---|
Booked, Dispatched, Origin, Transit, Destination | Active, on the board |
Pending, Waiting, Hold | Not yet active |
Delivered, Completed, Cancelled | Complete, off the board |
A shipment whose last trace is a Problem trace, or that is on hold, is flagged as an exception. A shipment priority we agree with you marks a load as hot.
What TrackFlo writes
Nothing, today. Check calls, stop times, driver details, status changes and proofs of delivery recorded in TrackFlo are not sent to Quantum Edge. Writing back through Quantum Edge's API is planned as a later phase. It needs an API key from Quantum Edge, and we scope which writes you want with you before we build them.
What your Quantum Edge admin sets up
Setup has four parts: a read-only database user, the tables the replica carries, the VPN, and a short list of details we confirm with you. If Quantum Edge hosts your database, their team and their hosting provider usually handle the first three, and we work with them directly.
1. A read-only database user on the replica
Create a MySQL user for TrackFlo on the replica, not on your primary database, with SELECT on your Quantum Edge schema and nothing else. Let it connect from the TrackFlo subnet we give you for the tunnel, not from our public IP: over the VPN, our traffic arrives from that private subnet.
GRANT SELECT ON `<schema>`.* TO '<user>'@'<TrackFlo subnet>';
-- Optional: lets us read replication status when we troubleshoot.
GRANT REPLICATION CLIENT ON *.* TO '<user>'@'<TrackFlo subnet>';Ask for SELECT, not SUPER. A user with only SUPER can connect and check replication, which looks like access is working, but cannot read a single table. On a replica that is not set to read-only, SUPER can also write.
2. The tables we read
Many Quantum Edge replicas copy only selected tables from the primary. We send you the list of tables we need during onboarding and check it against your replica before our first read.
3. A site-to-site VPN
The replica stays on its private network. TrackFlo reaches it through an IPsec site-to-site VPN that ends in our AWS environment. We agree the tunnel settings with your network team during onboarding, and pre-shared keys are exchanged by phone, never by email.
4. Credentials and onboarding details
Share the database username and password through a secure channel we agree on, not by email. We keep them in our secrets manager. We also confirm these with you before the first sync:
Which shipment types to read (truckload and partial by default) and the start date.
Which shipment priority marks a load as hot.
Which site contact types are your carriers' dispatch and after-hours contacts.
The time zone of your Quantum Edge server's clock, which stamps trace entry times.
Whether a tracking provider writes location pings into your traces.
Check that it's working
Pick a live shipment in Quantum Edge and find it in TrackFlo by its Quantum Edge shipment ID.
Enter a trace on that shipment in Quantum Edge. It appears on the load's timeline in TrackFlo within about a minute.
Change one of its stop appointments. TrackFlo shows the new time within a few minutes.
Both times are on top of your replica's replication delay.
A shipment in Quantum Edge never shows up in TrackFlo
Nothing in TrackFlo has updated for several minutes
TrackFlo can't reach the replica. The usual causes are a VPN tunnel that is down or a change to the database user's grants. Check the tunnel status on the firewall in front of the replica and tell us; we check our side. Updates resume on the next pass once the connection is back.
An update on the timeline reads "trace type" and a number instead of a name
That trace type isn't in the trace-type table we can read. Check that your trace-type table is on the replica's table list.
Things to know
Read-only by design. Every database session we open is set to read-only, so the database refuses a write even if one were attempted, and each query is capped at 60 seconds.
Updates arrive by polling. A change reaches TrackFlo on the next pass, plus however far the replica is behind your primary.
Times carry no time zone in Quantum Edge. We read appointments, arrivals and departures as local to the stop and find each stop's time zone from its ZIP code. Trace times are read as local to where the trace was recorded, from its coordinates or its city and state. Entry times use the server's clock.
Stops are put in travel order. Quantum Edge numbers every pickup before every delivery, so at a cross-dock its numbering isn't the order the truck visits. We order stops by arrival, then appointment, keeping the first pickup first and the last delivery last.
Multi-leg shipments. Each leg gets its own origin and destination from the leg record, so a cross-dock appears as the delivery of one leg and the pickup of the next. A trace goes to the leg whose carrier wrote it, otherwise to the first leg not yet delivered.
Removed stops are removed. When a stop is deleted in Quantum Edge, it leaves the load in TrackFlo on the next pass.
Unknown statuses keep the load on the board. A status outside the list above stays active until we map it, so a load never disappears because of a status we don't recognise.
Impossible dates are ignored. A date before 2000 or after 2100, such as the 1899-12-30 placeholder, is treated as empty.
Several carrier emails in one field. When a carrier email field holds a semicolon-separated list, the first address becomes the carrier's email in TrackFlo.
Not supported today: any write to Quantum Edge, and proof-of-delivery documents in either direction. The replica carries no documents, so we don't read PODs from Quantum Edge.